ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-13
8.3 Parameter Description
P0-xx Monitor Parameters
P0-00
VER Firmware Version
Address: 0000H
0001H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory Setting
Control
Mode
ALL
Unit
-
Range
-
Data Size
16-bit
Format
Decimal
Settings
This parameter shows the firmware version of the servo drive.
P0-01
ALE
Alarm Code Display of Drive (Seven-segment
Display)
Address: 0002H
0003H
Operational
Interface
Panel / Software Communication
Related Section:
11.1, 11.2, 11.3
Default
-
Control
Mode
ALL
Unit
-
Range
0x0000~0xFFFF: It only can be set to 0 to
clear the alarm (Same as DI.ARST).
Data Size
16-bit
Format
BCD
Settings
Hexadecimal format: displays the alarm code