Chapter 8 Parameters ASDA-A2
8-16 Revision February, 2017
122Sub-Index error occurs when accessing CANopen PDO 123
Data size error occurs when accessing CANopen PDO
124Data range error occurs when accessing CANopen PDO 125
CANopen PDO mapping object is read-only and write-
protected.
126CANopen PDO mapping object is not allowed in PDO
127CANopen PDO mapping object is write-protected when Servo ON
128Error occurs when reading CANopen PDO mapping object via
EEPROM
129Error occurs when writing CANopen PDO mapping object via
EEPROM
130The accessing address of EEPROM is out of range when using
CANopen PDO mapping object
131CRC of EEPROM calculation error occurs when using CANopen
PDO mapping object
132Enter the incorrect password when using CANopen PDO mapping
object
185Abnormal CAN Bus hardware
Alarm of Motion
201An error occurs when loading CANopen data
207Parameter group of PR#8 is out of range
209Parameter number of PR#8 is out of range
213 ~ 219An error occurs when writing parameter via PR procedure.
Please refer to Chapter 11 of the manual for further
information.
231The setting of monitor item of PR#8 is out of range
235PR command overflows
237Indexing coordinate is undefined
245 ~ 277Reserved
283Forward software limit
285Reverse software limit
289Feedback position counter overflows
291Servo OFF error
301CANopen fails to synchronize
302The synchronized signal of CANopen is sent too fast
303The synchronized signal of CANopen is sent too slow
304CANopen IP command is failed