ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-35
P0-49â– 
UAP Renew Encoder Absolute Position
Address: 0062H
0063H
Operational
Interface:
Panel / Software Communication
Related Section: N/A
Default:
0x0
Control
Mode:
ALL
Unit:
N/A
Range:
0x00 ~ 0x02
Data Size:
16-bit
Format:
Hexadecimaladecimal
Settings:This parameter is used to renew the absolute position data of the
encoder.
Parameter Renew Setting:
1: Renew the encoder data to parameters P0-50~P0-52 only.
2: Renew the parameters P0-50~P0-52, and clear the position error as
well. While this setting is activated, the current position of the motor
will be reset as the target position of position command (same
function as CCLR).
P0-50★
APSTS Absolute Coordinate System Status
Address: 0064H
0065H
Operational
Interface:
Panel / Software Communication
Related Section: N/A
Default:
0x0
Control
Mode:
ALL
Unit:
N/A
Range:
0x00 ~ 0x1F
Data Size:
16-bit
Format:
Hexadecimal
Settings:
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-E 1315 Series and is the answer not in the manual?

Delta ECMA-E 1315 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-E 1315 Series
CategoryServo Drives
LanguageEnglish

Related product manuals