Chapter 8 Parameters ASDA-A2
8-38 Revision February, 2017
to set the filter timing for the monitoring variable. The value of
monitoring variable will output after the filtering time determined by
parameter P0-53.
For example: when P0-09 is used
P0-54 ZON1L
General Range Compare Digital Output –
Lower Limit of 1st Monitoring Variable
Address: 006CH
006DH
Operational
Interface
Panel / Software Communication
Related Section: N/A
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
SettingsThe value of parameter P0-09 will change within the range between P0-
54 and P0-55 and then output after the filtering time determined by
parameter P0-53.
P0-55 ZON1H
General Range Compare Digital Output –
Upper Limit of 1st Monitoring Variable
Address: 006EH
006FH
Operational
Interface
Panel / Software Communication
Related Section: N/A
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit