ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-89
P1-82 VCMLPF
Filter Switching Time between P1-40 and P1-
81
Address: 01A4H
01A5H
Operational
Interface
Panel / Software Communication
Related Section:
Default
0
Control
Mode
S
Unit
msec
Range
0 ~ 1000 (0: disable this function)
Data Size
16-bit
Format
Decimal
Settings
0: Disabled
P1-83 VCMLPF Abnormal Analog Input Voltage Level
Address: 01A6H
01A7H
Operational
Interface
Panel/Software Communication
Related Section:
Default
0
Control
Mode
S
Unit
mV
Range
0 ~ 12000 (0: disable this function)
Data Size
16-bit
Format
Decimal
Settings When analog input voltage is over 50ms, AL.042 will occur. The
compared level for this parameter is the original analog input voltage
which has not been added by an offset value via parameter P4-22,
Analog Speed Input Offset.