Chapter 8 Parameters ASDA-A2
8-114 Revision February, 2017
P2-45 NCF3 Resonance Suppression (Notch filter) (3)
Address: 025AH
025BH
Operational
Interface
Panel / Software Communication
Related Section:
6.3.7
Default
1000
Control
Mode
ALL
Unit
Hz
Range
50 ~ 2000
Data Size
16-bit
Format
Decimal
Settings
The third group of mechanism resonance frequency setting value. If
P2-46 is set to 0, this function will be disabled. P2-23 and P2-24 are
the first group of resonance suppression (Notch filter).
P2-46 DPH3
Resonance Suppression (Notch filter)
Attenuation Rate (3)
Address: 025CH
025DH
Operational
Interface
Panel / Software Communication
Related Section:
6.3.7
Default
0
Control
Mode
ALL
Unit
dB
Range
0 ~ 32
Data Size
16-bit
Format
Decimal
Settings
The third group of resonance suppression (Notch filter) attenuation
rate. Set the value to 0 to disable the function of Notch filter.
P2-47 ANCF Auto Resonance Suppression Mode Setting
Address: 025EH
025FH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
1
Control
Mode
ALL