ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-121
P2-60 GR4 Gear Ratio (Numerator) (N2)
Address: 0278H
0279H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
128
Control
Mode
PT
Unit
pulse
Range
1 ~ (2
29
-1)
Data Size
32-bit
Format
Decimal
Settings
The numerator of electronic gear ratio can be selected via DI.GNUM0
and DI.GNUM1 (Please refer to table 8.1). If DI.GNUM0 and
DI.GNUM1 are not set, P1-44 will automatically be the numerator of
electronic gear ratio. Please switch GNUM0 and GNUM1 in stop status
to avoid the mechanical vibration.
P2-61 GR5 Gear Ratio (Numerator) (N3)
Address: 027AH
027BH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
128
Control
Mode
PT
Unit
pulse
Range
1 ~ (2
29
-1)
Data Size
32-bit
Format
Decimal
Settings
Please refer to the description of P2-60.