Chapter 8 Parameters ASDA-A2
8-154 Revision February, 2017
P4-12 SOF2 Analog Speed Input Offset Adjustment 2
Address: 0418H
0419H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
Factory default
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.
P4-13 TOF1 Analog Torque Input Offset Adjustment 1
Address: 041AH
041BH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
Factory default
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-E 1315 Series and is the answer not in the manual?

Delta ECMA-E 1315 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-E 1315 Series
CategoryServo Drives
LanguageEnglish

Related product manuals