Chapter 8 Parameters ASDA-A2
8-204 Revision February, 2017
P5-87 PLED E-CAM: Lead Pulse
Address: 05AEH
05AFH
Operational
Interface:
Panel / Software
Communication
Related Section:
7.11
Default:
0
Control
Mode:
PR
Unit:
-
Range:
-1073741824 ~ +1073741823
Data Size:
32-bit
Format:
Decimal
Settings:
When the engaging condition (P5-88.Z) of E-cam is satisfied, the pulse
number from the master has to exceed the setting value of this
parameter, so that E-cam is fully engaged.
In other words, E-cam engages after neglecting the lead pulse
specified by this parameter.
If the symbol of this parameter is +, it means the received forward pulse
is regarded as the lead pulse.
If the symbol of this parameter is - , it means the received reverse
pulse is regarded as the lead pulse.
NOTE
A2L does not support E-Cam function.
P5-88â–
ECON E-CAM: Activate E-Cam Control
Address: 05B0H
05B1H
Operational
Interface:
Panel / Software Communication
Related Section:
7.11
Default:
00000000h
Control
Mode:
PR
Unit:
-
Range:
0 ~ 0x203FF257
Data
Size:
32-bit
Format:
Hexadecimal