ASDA-A2 Chapter 11 Specifications
11-6 Revision February, 2017
Note:
*1 When it is in rated load, the speed ratio is: the minimum speed (smooth operation) /rated speed.
*2 When the command is the rated speed, the velocity correction ratio is: (rotational speed with no load –
rotational speed with full load) / rated speed.
*3 TN system: The neutral point of the power system connects to the ground directly. The exposed metal
components connect to the ground via the protective earth conductor.
4 Please refer to section 11.6 for overload features.