Table 17: Technical Specifications of Delta PCS100 (Continued)
Table 18: Icc declaration (r.m.s. value, Icp,mr, device)
Item
Description
Crest Factor
2.0 @ rated power
Environment
Max Altitude
3,000 m
Operating Temperature
≤ 2000 m: -25 ~ 60ºC, derating > 50ºC (3%/ºC),
-25 ~ 40ºC, > 2000 m
Storage Temperature
-25 ~ 70ºC
Humidity
0 to 95% RH, no-condensing
Cooling
Fan cooled, speed controlled and alarmed signal
Pollution Degree
3
Acoustic Noise
< 72 dB, @ 1m
IP Degree
IP55
Interface & Communication
Digital I/O
3 x Input, 0 - 24 V
2 x Output relays
User Interface
4.9 inch LCD screen with operation button, Fault LEDs
Emergency Stop
Local EPO button & remote control
Communication
RS-485 / Modbus RTU, Ethernet/ Modbus TCP
System Characteristic
Peak Efficiency
97.9%
Standby Loss
< 25 W @Sleep Mode
Dimensions (W x D x H) (excl.
Package)
600 mm x 800 mm x 1,766 mm / 23.6 in x 31.5 in x 69.5 in
Net Weight (excl. Package)
310 kg / 683 lbs
Standard Compliance
Certificate
IEC/EN 62477-1,
VDE-AR-N4105, G99, AS/NZS 4777.2
IEC/EN 61000-6-2, IEC/EN 61000-6-4 (Class A)
Product Conformity
CE, RCM
Applicable Battery Chemistry
Lithium-ion, flow battery
Characteristics of SCPD
Ports
Icc
Icp,mr
Type
Location
Specification
AC
25kA
5kA
170M1371,
Bussmann
FU1, FU2,
FU3
Rated current: 250A; rated voltage:690V;
Interrupt rating: 200kA RMS Sym.
DC
20kA
5kA
170M1813,
Bussmann
FU4,FU5
Rated current: 250A; rated voltage:1000V;
breaking capacity: 50kA.