(3) Unstable
When the weight value is not stable, the Unstable in the bulletin is highlighted in a red block. When the weight value
is stable, the Motion in the bulletin is highlighted in a green block.
(4) Cal. Issue
When an error occurs, for example, putting a higher value for a lighter weight, even if the calibration is done, the Cal.
Issue in the bulletin is highlighted in a red block. When this warning appears, the weight value is not reliable.
(5) Overflow
After calculation, the load weight on the weighing platform converts to a digital value. If the digital value exceeds the
maximum allowable number, the Overflow in the bulletin is highlighted in a red block.
(6) Max
You can set up a weight maximum limit in the Load Cell Setup page. When the weight used exceeds the maximum
limit, the Max in the bulletin is highlighted in a red block.
(7) Power
When the power supply is abnormal, the Power in the bulletin is highlighted in a red block.
(8) Zero Reset
Reset the present value to zero.
(9) Unit Setup
Here you can select the weight unit, in kilogram or in gram.