TP70P-211LC1T/TP04P-20EXL1T Operation Manual
5-10
D
Content
OFF
ON
STOP
RUN
RUN
STOP
Attrib.
Latched
Default
D1462 Data length to be written on Slave ID#13 - - - R/W YES 16
D1463 Data length to be written on Slave ID#14 - - - R/W YES 16
D1464 Data length to be written on Slave ID#15 - - - R/W YES 16
D1465 Data length to be written on Slave ID#16 - - - R/W YES 16
D1480
↓
D1495
The data which is read from slave ID#1 in PLC LINK at
the time when M1353 is OFF.
0 - - R NO 0
The initial data register where the data read from slave
ID#1~ID#16 in PLC LINK is stored at the time when
M1353 is ON
- - - R YES 0
D1496
↓
D1511
The data which is written into slave ID#1 in PLC LINK at
the time when M1353 is OFF.
0 - - R/W NO 0
The initial data register where the data written into slave
ID#1~ID#16 in PLC LINK is stored at the time when
M1353 is ON.
- - - R/W YES 0
D1512
↓
D1527
The data which is read from slave ID#2 in PLC LINK 0 - - R NO 0
D1528
↓
The data which is written into slave ID#2 in PLC LINK 0 - - R/W NO 0
D1544
↓
The data which is read from slave ID#3 in PLC LINK 0 - - R NO 0
D1560
↓
D1575
The data which is written into slave ID#3 in PLC LINK 0 - - R/W NO 0
D1576
↓
The data which is read from slave ID#4 in PLC LINK 0 - - R NO 0
D1592
↓
The data which is written into slave ID#4 in PLC LINK 0 - - R/W NO 0
D1608
↓
The data which is read from slave ID#5 in PLC LINK 0 - - R NO 0
D1624
↓
The data which is written into slave ID#5 in PLC LINK 0 - - R/W NO 0
D1640
↓
D1655
The data which is read from slave ID#6 in PLC LINK 0 - - R NO 0
D1656
↓
The data which is written into slave ID#6 in PLC LINK 0 - - R/W NO 0