EasyManuals Logo

Delta VFD-ED Series User Manual

Delta VFD-ED Series
447 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
Chapter 7 Option Cards | VFD-ED
7-29
When OUT/M, IN/M set to 0 and 0, the PG card input signal A-/A, B-/B are square waves while AO-
AO
, BO-
BO
are frequency division output.
When OUT/M, IN/M are set to 1 and 0, the PG card input signal A-/A, B-/B are square waves while the
BO-
BO
is the A and B phase indicator (for example, when
BO-
BO
is LOW, it means A is ahead of B:
when
BO-
BO
is HIGH, it means B is ahead of A).
AO-
AO
is frequency division output.
When OUT/M, IN/M are set to X and 1, B-/B phase has to be the direction indication input signal (for
example, when B-/B is LOW, it means A is ahead of B; when B-/B is HIGH, it means B is ahead of A).
A-/A is a square wave input, BO-
BO
and B-/B phase are input into synchronous action;
AO-
AO
is
frequency division output.
Take Pr.10-29 and Pr.10-30 as examples: When the frequency division value is 15, OUT/M =1, IN/M =
0. Set Pr.10-29 = 15 and Pr.10-30 = 0002h.
Set Pr.10-29 =15
Set Pr.10-30 =0002h
Bit3 Bit2 Bit1 Bit0
X X 1 0