Chapter 11 Summary of Parameter SettingsMS300 (High Speed Model)
11-30
Pr. Explanation Settings
Factory
Setting
09-42 CANopen control status
0: Not ready for use state
1: Inhibit start state
2: Ready to switch on state
3: Switched on state
4: Enable operation state
7: Quick stop active state
13: Error reaction activation state
14: Error state
Read
Only
09-43
CANopen reset index
bit 0: CANopen reset, the internal address 20XX is 0
bit 1: CANopen reset, the internal address 264X is 0
bit 2: CANopen reset, the internal address 26AX is 0
bit 3: CANopen reset, the internal address 60XX is 0
65535
09-60
Identifications for communication
card
0: No communication card
1: DeviceNet slave
2: Profibus-DP slave
3: CANopen slave
4: MODBUS -TCP slave
5: EtherNet/IP slave
10: Backup power supply
##
09-61
Firmware version of communication
card
Read only
##
09-62
Product code
Read only
##
09-63
Error code
Read only
##
09-70
Address of communication card
DeviceNet: 0-63
Profibus-DP: 1-125
1
09-71 Setting of DeviceNet speed
Standard DeviceNet:
0: 125 Kbps
1: 250 Kbps
2: 500 Kbps
3: 1 Mbps (Delta Only)
Non-standard DeviceNet: (Delta Only)
0: 10 Kbps
1: 20 Kbps
2: 50 Kbps
3: 100 Kbps
4: 125 Kbps
5: 250 Kbps
6: 500 Kbps
7: 800 Kbps
8: 1 Mbps
2