NO.5 Function List
14
No.5 Function List
Description of special symbols:
* indicates that this parameter content has various set values or it shall be specifically set
based on actual situation.
Ex-factory value refers to parameter value set during delivery of inverter or parameter value
refreshed while the user restores ex-factory operation.
Alteration refers to alternative attribute of the parameter. indicates that the alteration is
available during shutdown and operating, × indicates that the alteration is unavailable
during operating, and Δ refers to read-only parameter which cannot be altered by the user.
5.1 Basic function parameters
Function
code
Name of function
Setting range and data content
Ex-factory
value
P000
Parameter locking
0: Invalid 1: Valid
0
P001
Control mode
0: Manipulator
1: External terminal
2: Communication port
0
P002
Frequency setting
selection
0: Manipulator
1: External terminal
2: Communication port
3: Manipulator potentiometer
0
P003
Main frequency
0.00-400.00 Hz
*
P004
Reference
frequency
0.01-400.00 Hz
50.00
P005
Maximum operating
frequency
10.00-400.00 Hz
50.00
P006
Intermediate
frequency
0.01-400.00 Hz
2.5/3.0
P007
Minimum frequency
0.01-20.00 Hz
0.50
P008
Maximum voltage
0.1V-*
220/380
P009
Intermediate voltage
0.1V-*
*
P010
Low-frequency
torque boost voltage
0.1V-50.0V
*
P011
Lower frequency
0.00-400.00 Hz
0

Table of Contents