NO.6 Detailed Function Description
55
P117
Setting Range
Unit
Ex-factory Value
Alteration
Memory function for
internally controlled
multi-segment speed
0-1
1
0
0: Not memorized 1: Memorized
This parameter determines the pause function during inverter control at internally controlled
multi-segment speed; when P117=1, it can memorize the inverter operating state, and can
even memorize during stop or failure, then continue to run after back to normal; when
P117=0, memorizing is unavailable.