Page #24 background image
24
AVR-3310CI/AVR-3310/AVR990/AVC-3310
5F
Invalid data in firmware such as
Sub CPU, DSP, FPGA, and PLD
for rewriting sent from DM860
(invalid data received).
Turn the power off then back on.
Updating starts automatically.
60
NACK received when “P” com-
mand sent to Sub CPU, DSP,
FPGA, PLD etc.
Turn the power off then back on.
Updating starts automatically.
61
NACK received when “I” command
sent to Sub CPU, DSP, FPGA,
PLD etc.
Turn the power off then back on.
Updating starts automatically.
80
Failure to acquire serial flash data
and before deleting serial flash.
Turn the power off then back on.
Updating starts automatically.
81
Failure to delete data before rewrit-
ing serial flash.
Turn the power off then back on.
Updating starts automatically.
82
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when timed out).
Turn the power off then back on.
Updating starts automatically.
83
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when an error).
Turn the power off then back on.
Updating starts automatically.
84
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when a Check Sum error).
Turn the power off then back on.
Updating starts automatically.
85
Failure to receive firmware for
serial flash rewriting sent by
DM860 (when invalid data
received).
Turn the power off then back on.
Updating starts automatically.
86
Failure to rewrite when writing data
in serial flash.
Turn the power off then back on.
Updating starts automatically.
A0
Failure to acquire (Application
Mode) IP address before rewriting
DM860 (AutoIP).
Check the network connection.
Carry out the update in an environment
that has little network load.
A1
Failure to acquire (Application
Mode) IP address before rewriting
DM860 (when timed out).
Check the network connection.
Carry out the update in an environment
that has little network load.
A2
Notification of invalid login via
DPMS access when rewriting
DM860 related firmware (Applica-
tion Mode).
Check the network connection.
Carry out the update in an environment
that has little network load.
A3
Notification of line congestion via
DPMS access when rewriting
DM860 related firmware (Applica-
tion Mode).
Check the network connection.
Carry out the update in an environment
that has little network load.
A4
Notification of connection failure
via DPMS access when rewriting
DM860 related firmware (Applica-
tion Mode).
Check the network connection.
Carry out the update in an environment
that has little network load.
Error
code
Details of Error code Display Coping strategies
w
w
w
.
x
i
a
o
y
u
1
6
3
.
c
o
m
Q
Q
3
7
6
3
1
5
1
5
0
9
9
2
8
9
4
2
9
8
T
E
L
1
3
9
4
2
2
9
6
5
1
3
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299
http://www.xiaoyu163.com
http://www.xiaoyu163.com

Other manuals for Denon AVR-3310CI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Denon AVR-3310CI and is the answer not in the manual?

Denon AVR-3310CI Specifications

General IconGeneral
BrandDenon
ModelAVR-3310CI
CategoryStereo Receiver
LanguageEnglish

Related product manuals