Loading...
When the results of check item (54) are "00"
(Detection of HPD is not OK / Detection of RXSENSE is not OK )
Check item(60). Checking the HPD and RXSENSE. :
Does the test point of RXSENSE close to the HDMI output terminal
[JK751] indicate the 3.3 V?
Does the voltage of HPD test point close to the HDMI output terminal
[JK751] indicate "Hi" (3-5 V)?
JK751
HDMI OUT
[MONITOR]
D2+
D2-
D1+
D1-
D0+
D0-
CK+
CK-
HPD
Check the RXSENSE/HPD. (Monitor)
HDMI Rx/Tx [IC721] is faulty.
Replace with a new device.
Recheck from check item (3).
If it does not work, replace the PCB.
Check for a short circuit in the TMDS/ HPD line.
If there is no problem, the HDMI Rx/Tx (IC721) is faulty.
Replace with a new device.
NOYES
103