FIREPLACE INSTALLATION
Continued
Figure 49 - Installing Battery Into
Handset WRC
HIGH ALTITUDE INSTALLATION
Your DESA Heating, LLC direct-vent replace
has been tested and approved in the USA for
elevations from 0-2000 feet (610 m) .
High altitude models as indicated by the letter
sufx (-HA) are equipped with specic gas
controls for installation above 4000 feet.
IMPORTANT: Fireplaces when factory
equipped for use at high altitude can not be
converted for use with propane/LP gas. When
installing a non-high altitude replace at an
elevation above 2000 feet (610 m) (in the
USA), you may need to decrease the input
rating by changing the existing burner orice
to a smaller size. Reduce input 4% for each
1000 feet (305 m) above sea level. Check
with your local gas company for proper derate
procedure and orice size.
Consult your local gas company to help deter-
mine the proper orice for your location.
For assistance with any high altitude installation
call DESA Heating, LLC at 1-866-672-6040.

Use proper gas type for the replace unit you
are installing. If your gas supply is not correct,
do not install replace. See retailer where you
purchased the replace for proper replace
according to your gas type or to purchase gas
conversion kit (see Accessories, page 52).
INSTALLING GAS pIpING TO
FIREpLACE LOCATION

   


  
   

  
   


Installation Items Needed
Before installing replace, make sure you
have the items listed below.
external regulator (supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection *
sediment trap
tee joint
pipe wrench
approved exible gas line with gas connec-
tor (if allowed by local codes)
* A CSA design-certied equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the CSA design-certied equipment shutoff
valve from your retailer.
For propane/LP connection only, the installer must
supply an external regulator. The external regula-
tor will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11" and
14" of water. If you do not reduce incoming gas
pressure, replace regulator damage could occur.
Install external regulator with the vent pointing
down as shown in Figure 50, page 28. Pointing
vent down protects it from freezing rain or sleet.
Battery
Cover
12 Volt
Battery
Back of
Handset
4. Once battery is activated unit is ready to
use.
5. Replace bottom louver panel.