www.desatech.com
116035-01J30
FIREPLACE INSTALLATION
Continued
pRESSURE TESTING FIREpLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
53, page 29).
2. Open propane/LP supply tank valve for
propane/LP replace or main gas valve
located on or near gas meter for natural
gas replace.
3. Make sure control knob of replace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 54 or Figure
55 on page 29). Apply noncorrosive leak
detection uid to all joints. Bubbles form-
ing show a leak. Retighten all ttings
5. If leaks still exist, turn off gas supply and
call a qualied service person.
6. Light replace (see Operation, page 32).
Check all other internal joints for leaks.
7. Turn off replace (see To Turn Off Gas to
Appliance, page 33 or 36 depending on
model).
DOOR
Replacement Parts
-
-
-
1. Grasp lower louver panel and pull up until
hanger brackets release from door pins
(see Figure 56).
2. Swing louver panel out until it clears re-
place opening.
Figure 56 - Removing Lower Louver
Access Panel
Door Pin
Hanger Bracket
Lower Louver
Access Panel
3. Pull entire panel out until bottom tabs are
free of slot openings in lower face frame.
Figure 57 - Removing Top Louver Trim
Panel
Panel Tabs
Top Louver
Trim Panel
Door Pin
Hanger
Bracket
1. Grasp two hanger brackets at bottom and
pull up until hanger brackets release from
door pins (see Figure 57).
2. Swing out bracket ends until upper panel
tabs can be angled out of slot openings
in upper face frame.
3. Pull entire louver trim panel out of face
frame.