Blast chiller Service Manual
3
Rev 07/04/2015
Parameter
Description
5 PANS
115V
5 PANS
230V
SELF
CONTAINED
230V TROLLEY
OF8 core probe point 5 offset [°C/°F] 0 0
0 0
SLL not used -40
-40 -40 -40
SLH not used 3
3 3 3
RHU cabinet RH% set point settable [num] 80
80 80 80
MNS mains voltage alarm limit [%] 20
20 20 20
MAL voltage alarm delay [hours] 10
10 10 10
MEV
max number of voltage conditions before voltage
alarm [num]
5
5 5 5
MBP
time range in which is performed the mains
voltage control [hours]
1
1 1 1
RL1 relay 1 action type [num] 1
1 1 1
RL2 relay 2 action type [num] 13
13 13 17
RL3 relay 3 action type [num] 17
17 17 13
RL4 relay 4 action type [num] 13
13 13 13
RL5 relay 5 action type [num] 0
0 0 0
RL6 relay 6 action type [num] 11
11 11 11
RL7 relay 7 action type [num] 10
10 10 10
RL8 relay 8 action type [num] 1
1 1 1
SRV remaining time before maintenance [day] 800
800 800 800
PCA cabinet set point in prechilling [°C/°F] 28 28
28 28
PCF evaporator fan speed in prechilling [num] 10
10 10 10
PFA cabinet set point in prefreezing [°C/°F] -22 -22
-22 -22
PFF evaporator fan speed in prefreezing [num] 10
10 10 10
DWA load tolerance on relays [%] 20
20 20 20
STO max storage time without hot gas defrost [hours]
48
48 48 48
DFS
difference between core probe
and cabinet
probe to detect core probe inserted [°C/°F]
18 18
18 18
STE sterilization cycle duration [sec] 300
300 300 300
PRH heating core probe cycle duration [sec] 60
60 60 60
VOF mains voltage sensor offset [num] 77
77 77 77
PTE not used 20
20 20 20
PTI not used 12
12 12 12
MRT max recharging time of battery [hours] 20
20 20 20
FCD max first recharging time of battery [hours] 12
12 12 12
BTD max duration of battery test [sec] 3
3 3 3
TBT consecutive battery test interval time [min] 5
5 5 5
NMT not used 250
250 250 250
VRS start battery charging threshold [V/10] 11,1
11,1 11,1 11,1
VRE end battery charging threshold [V/10] 11,3
11,3 11,3 11,3
VRT
battery voltage at ending charging for max
duration [V/10]
9,8
9,8 9,8 9,8
VBR
minimum
battery voltage for disabling battery
[V/10]
8,6
8,6 8,6 8,6
VAD battery voltage threshold to show "no battery" 3,3
3,3 3,3 3,3