Slow fluid leak from fluid tip and
needle seat.
Incorrect fluid tip for fluid needle
fitted to gun.
Check tip/needle selection chart
and fit correct item.
Incorrect fluid tip for fluid needle
fitted to gun.
Check tip/needle selection chart
and fit correct item.
Major fluid leak or fluid jetting
from fluid tip and needle seat.
Contamination on needle or tip
mating surfaces preventing good
seal.
Slow fluid leak from needle
packing.
Remove tip and needle and
thoroughly clean.
Contamination on needle or tip
mating surfaces preventing good
seal.
Lubricate packing. (GL-1)
Tighten or replace as necesarry.
Fluid needle packing worn or
loose.
Fluid needle external profile
damaged or worn.
Fluid tip internal seat scored
damaged or worn.
When removing air cap from retaining ring, do not remove the ring seat from the retaining ring.
Damage to the parts may occur. Simply wipe parts clean and reassemble with new or clean air cap.