CODE POSSIBLE CAUSE POSSIBLE SOLUTION
6 Defective safety valve Operate safety valve manually by pulling on ring. If valve still leaks, it must
be replaced.
7
Regulatorisnotadjustedcorrectlyforacces-
sory being used
Itisnormalforsomepressuredroptooccurwhenanaccessoryisused,adjust
the regulator as instructed in Regulator under Features if pressure drop is
excessive.
NOTE:Adjusttheregulatedpressureunderflowconditionswhileaccessory
is being used.
8 Prolonged excessive use of air Decrease amount of air usage.
9 Compressor is not large enough for acces-
sory
Check the accessory air requirement. If it is higher than the CFM or pressure
supplied by your air compressor, a larger compressor is needed to operate
accessory.
10 Hole in air hose Replace air hose.
11 Check valve restricted Contact a D
e
WALT factory service center or a D
e
WALT authorized service
center.
12 Air leaks Tighten fittings.
13 Regulator is damaged Replace.
14 Motor overload protection switch has tripped See Motor Overload under Features.
15 Extension cord is wrong length or gauge Check for proper gauge wire and cord length. See Extension Cords under
Installation.
16
Loose electrical connections Contact a D
e
WALT factory service center or a D
e
WALT authorized service
center.
17
Possible defective motor. Contact a D
e
WALT factory service center or a D
e
WALT authorized service
center.