159
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
::= { datakinetics 1 }
-- ------------------------------------------------------------------------
-- ------------------------------------------------------------------------
-- Top level nodes within DK4032 MIB.
--
dkSysInfo OBJECT IDENTIFIER ::= { datakinetics 2 }
-- ------------------------------------------------------------------------
-- ------------------------------------------------------------------------
-- The system information branch
--
dkSysAlarms OBJECT IDENTIFIER ::= { dkSysInfo 4 }
-- ------------------------------------------------------------------------
-- The Alarms branch
--
dkAlrmCategory OBJECT IDENTIFIER ::= { dkSysAlarms 1 }
dkAlrmPcm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active PCM alarms"
::= { dkAlrmCategory 1 }
dkAlrmSig OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active signaling alarms"
::= { dkAlrmCategory 2 }
dkAlrmSys OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active system alarms"
::= { dkAlrmCategory 3 }
dkAlrmClass OBJECT IDENTIFIER ::= { dkSysAlarms 2 }
dkClass1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active Class 1 alarms"
::= { dkAlrmClass 1 }
dkClass2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active Class 2 alarms"
::= { dkAlrmClass 2 }
dkClass3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active Class 3 alarms"
::= { dkAlrmClass 3 }
END
-- ------------------------------------------------------------------------
-- ------------------------------------------------------------------------