EasyManua.ls Logo

Dialogic SS7G2X - Remote Operations; Remote Operation Types

Dialogic SS7G2X
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
5.2 Remote Operations
Table 3 gives the possible remote operation types.
TIME
Time of day in the format:
xx:yy:zz
where:
xx – 2 digit hour
yy – 2 digit minute
zz – 2 digit second
xx – 00 to 23
yy – 00 to 59
zz – 00 to 59
TLO Auto log off time (in minutes) 1 to 60 Default = 30
TLOW Log off warning time (in minutes) 0 to 60 Default = 25
TMSEC
Timer values in milliseconds associated with
a timer number (resolution is 100ms)
100 to 10000
(in integer multiples
of 100)
TO
Signaling system dependent timer number.
As specified in the particular signaling
system’s list of timers.
1 to 999
TS
A timeslot within a PCM interface on a board
in the format:
xx-y-zz
where:
xx = board position (BPOS)
y = PCM within a board
zz= Timeslot
xx – 1 to 3
y – 1 to 4
zz – 1 to 31
TSEC
Timer values in seconds associated with a
timer number
1 to 3000
TTYPE
Timer Type
See Section 5.3, “Signaling Gateway
Timers” on page 38 for definitions of
Signaling Gateway “CONV” specific timers.
One of:
•MTP3
•MTP3A
•SCTP
•CONV
USER User name
0 to 12
<text character>
Table 2. Parameter Definitions (Continued)
Name Description Range Notes
Table 3. Remote Operation Types
DTYPE Description
SOFTWARE Selecting this operation allows the user to upload a new software version.
CONFIG
Selecting this operation allows the user to upload a previously backed up version of the
configuration.
LICENSE Selecting this operation allows the user to upload new software licenses.

Table of Contents