EasyManua.ls Logo

Dialogic SS7G2X - MMLOS - MML Log off Set; MMPTC - MML Port Change

Dialogic SS7G2X
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
Chapter 6 Command Definitions
6.8.3 MMLOS – MML Log Off Set
Synopsis
This command sets the current log-on time-out (TLO) and timeout warning (TLOW) parameters. If TLOW is
set to zero, the automatic time-out is disabled. If port (PORT) is omitted, the command applies to all ports.
Syntax
MMLOS:{[TLO=,][TLOW=,]}[PORT=,];
Prerequisites
None
Attributes
CONFIG
Examples
MMLOS:TLO=35;
MMLOS:TLOW=19;
6.8.4 MMPTC – MML Port Change
Synopsis
This command sets the data input/output parameters for serial and telnet data ports.
Note: Only serial port 2 (COM2) is accessible by the user.
Syntax
MMPTC:PORT=,{[BAUD=,][DBITS=,][PARITY=,][SBITS=,][LINES=,][PTMODE=,]};
Prerequisites
No user must be logged on to the port affected.
For the telnet ports, only the LINES parameter can be changed.
Attributes
CONFIG
Examples
MMPTC:PORT=2,BAUD=300;
MMPTC:PORT=2,SBITS=2;

Table of Contents