EasyManuals Logo

Dibal Mistral M-520 User Manual

Dibal Mistral M-520
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
USER´S MANUAL
49-M500WMEN25
72
MENU
5 4
MENU
5 4 1
MENU
5 4 1 1
0
MENU
MENU
5 4 1 2
0 0 0 0
MENU
MENU
5 4 1 3
6 0 0 0
MENU
MENU
5 4 1 4
+
++
+
MENU
MENU
5 4 1 5
+
++
+
MENU
PROG 5.4
COMMUNICA 4
-
4
INTERCONEXION
PROG 5.4.1
INTERCONE 1
-
2
C
ONFIGURAC M/E
PROG 5.4.1.1
M E CONFI 1
-
5
NET IDENTIFIER
PROG 5.4.1.2
MAESTRA…………………0
SCALE ADD
PROG 5.4.1.3
6000
UDP PORT
SLAVE 01
ADDRESS IP
000000000000
n0 SLAVES
COMMUNICATED
SLAVES COMMUNICATED
7.4. SCALE NETWORK [ 5 4 ]
To acces to this menu press MENU (2 secs) 5 4.
7.4.1.Master slave
When a scale is setted up as a master the next submenu will
appeared.
7.4.1.1. Set up as MASTER-SLAVE [ 5 4 1 ]
To acces to this menu press MENU (2 secs) 5 4.1.
1. Network identification [ 5 4 1 1 ]
This parameter is assigned to a 4 digit number to identify the
network that will work in.
1. Acces pressing MENU (2 secs) 5 4 1 1.
2. Enter the wanted value and press
.
3. Press MENU in order to exit the configuration menu.
2. Scale address [ 5 4 1 2 ]
This parameter is assigned to the address of the scale. The
parameter may be between 00 and the maximum number of
slaves that this model can have. If you want to set as Master,
introduce 00. If you want to configure as Slave, introduce a value
between 01 and the maximum number of slaves depending on
the scale model.
1. Acces pressing MENU (2 secs) 5 4 1 2.
2. Enter the wanted value and press
.
3. Press MENU in order to exit the configuration menu.
3. UDP Port (6000) [ 5 4 1 3 ]
This parameter is assigned to the number of port that the master
and slave communication is done, being a 4 digit number
1. Acces pressing MENU (2 secs) 5 4 1 3.
2. Enter the wanted value and press
.
3. Press MENU in order to exit the configuration menu.
4.Ip slaves address [ 5 4 1 4 ]
I n this parameter you display the IP of the slaves which the
master it connected.
1. Acces pressing MENU (2 secs) 5 4 1 4.
2. Press
+
++
+
to display the next slave connected or
or to
display the previous one.
3. Press MENU in order to exit the configuration menu.
5. Slaves connected [ 5 4 1 5 ]
This parameter is assigned to displayed the addresses of the
connected slaves scales
1. Acces pressing MENU (2 secs) 5 4 1 5.
2. Press
+
+ +
+
or
to display the next or the previous screen, if
it is not enough space in the screen to all the slaves scales
addresses.
3. Press MENU in order to exit the configuration menu.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dibal Mistral M-520 and is the answer not in the manual?

Dibal Mistral M-520 Specifications

General IconGeneral
BrandDibal
ModelMistral M-520
CategoryScales
LanguageEnglish

Related product manuals