Ā© 2014 Digi International Inc. 62
XBee/XBee-PRO
Ā®
DigiMesh 2.4 User Manual
Security
FN
Find Neighbors. Discovers and reports all RF modules
found within immediate RF
range. The following information is reported for each
module discovered.
MY<CR> (always 0xFFFE)
SH<CR>
SL<CR>
NI<CR> (Variable length)
PARENT_NETWORK ADDRESS<CR> (2 Bytes) (always
0xFFFE)
DEVICE_TYPE<CR> (1 Byte: 0=Coord, 1=Router, 2=End
Device)
STATUS<CR> (1 Byte: Reserved)
PROFILE_ID<CR> (2 Bytes)
MANUFACTURER_ID<CR> (2 Bytes)
DIGI DEVICE TYPE<CR> (4 Bytes. Optionally included
based on NO settings.)
RSSI OF LAST HOP<DR> (1 Byte. Optionally included
based on NO settings.)
<CR>
If the FN command is issued in command mode, after
(NT*100) ms + overhead time,
the command ends by returning a <CR>.
If the FN command is sent through a local API frame,
each response is returned as a separate Local or Remote
AT Command Response API packet, respectively. The data
consists of the above listed bytes without the carriage
return delimiters. The NI string will end in a ā0x00ā null
character.
AT Comand Name and Description
Parameter
Range
Default
EE
Security Enable. Enables or disables 128-bit
AES encryption. This command parameter
should be set the same on all devices..
0 to 1 0
KY
Security Key. Sets the 16 byte network
security key value. This command is write-
only. Attempts to read KY will return an OK
status. This command parameter should be set
the
same on all devices.
128-bit value n/a
ATļ
Command
Name and Description
Parameter
Range
Default