A-9
System OK LED Flashing
Message: Local967Parameter checksum error detected in NVRAM
Problem: Self-test has detected a checksum error in nonvolatile random-access
memory (NVRAM) parameters.
Correction: Reset the DECserver to the factory settings by pulling out the power
cord and reinserting it while pressing the system reset switch until the
System OK LED flashes. If this fails to correct the problem, notify the
network manager that the DECserver must be returned to Digital
Network Products Group for repair or for replacement. Refer to the
Network Access Software Problem Solving Guide for information
about returning the DECserver.