ASCII HEX Function Description Return String
V99G0302 56 39 39 47 30 33 30 32 0D Get AV Mute Pn/F
V99S0302n 56 39 39 53 30 33 30 32 n 0D Set AV Mute P/F
V99G0304 56 39 39 47 30 33 30 34 0D Get Image Freeze Pn/F
V99S0304n 56 39 39 53 30 33 30 34 n 0D Set Image Freeze P/F
V99G0308 56 39 39 47 30 33 30 38 0D Get Projection
Mode
0: Front
1: Rear
2: Ceiling + Front
3: Ceiling + Rear
Pn/F
V99S0308n 56 39 39 53 30 33 30 38 n 0D Set Projection
Mode
0: Front
1: Rear
2: Ceiling + Front
3: Ceiling + Rear
P/F
V99G0309 56 39 39 47 30 33 30 39 0D Get Vertical
Keystone
n= -80~80 Pn/F
V99S0309n 56 39 39 53 30 33 30 39 n 0D Set Vertical
Keystone
n= -80~80 P/F
Command Group 04 (Remote Control buttons)
ASCII HEX Function Description Return String
V99S0401 56 39 39 53 30 34 30 31 0D ON P/F
V99S0402 56 39 39 53 30 34 30 32 0D OFF P/F
V99S0403 56 39 39 53 30 34 30 33 0D Focus+ P/F
V99S0404 56 39 39 53 30 34 30 34 0D Focus- P/F
V99S0405 56 39 39 53 30 34 30 35 0D Zoom + P/F
V99S0406 56 39 39 53 30 34 30 36 0D Zoom - P/F
V99S0408 56 39 39 53 30 34 30 38 0D LENS SHIFT P/F
V99S0409 56 39 39 53 30 34 30 39 0D UP P/F
V99S0410 56 39 39 53 30 34 31 30 0D DOWN P/F
V99S0411 56 39 39 53 30 34 31 31 0D LEFT P/F
V99S0412 56 39 39 53 30 34 31 32 0D RIGHT P/F
V99S0413 56 39 39 53 30 34 31 33 0D ENTER P/F
Continued
Notes
Note: spaces are shown in the
examples for clarity, but are NOT
used in the actual commands or
replies.
IntheAsciicolumn,thenal[CR]
has been omitted for clarity.
In the Command Strings and the
Return Results, ‘n’ represents a
data string.
In the Return Result Strings:
‘P’ is returned for a successful Set
command;
‘Pn’ is returned for a successful Get
command;
‘F’ is returned for a failed command.
When Standby Mode is set to Eco:
the RS232 connection is disabled,
so it will not be possible to turn the
projector On remotely, except via the
LAN connection.