SEEDING CONTROL
18
084500 */ha
JJJJJJJJJJJJJJJJ
JJJJJJJJJJJJJJJJ
CONTROL OF POPULATION RATIO
You can read the ratio of the desired and the actually measured population in
each row, displayed with bar graphs.
Use this function for seeds that can be detected precisely by the photoelectric
cells (seeds larger than 5 mm, such as maize, sunflower, sugar beet, etc)
Necessary basic data
Optimal seed spacing
Distance traveled in 100 speed signals
Working width
Any measurement results true values only if basic data are entered correctly!
Start
:
Display
Do not mix up the actual seed/ha value displayed here with the total area seed/ha,
which is shown by pushing the INFO button! See also STORED SEEDING DATA.
Alarm
The monitor alarms you when difference goes beyond min. or max. limit
values. (See detailed description at SETTING MIN. AND MAX. LIMITS FOR
POPULATION CONTROL.)
If the row error is sustained, the audible error signal is continuously. If a row
is excluded from seeding, must skip it from controlling too. (See SETTING
ROW SKIP)
J
JDJ
When you start this function this screen
appears until sufficient data for displaying are
collected (cca.10 meters).
The accuracy of seeding can be surveyed
simply and visibly from 0-150 % with a
resolution of 6.25 %. Bar graphs and actual
seed/ha value are calculated over seeded
grains in cca. 40 meters distance traveled.

Related product manuals