MAINTENANCE, STORAGE
24
THE MONITOR INDICATES BLOCKAGE AT A SEED
MODULE FOLLOWING TEST AND EVEN AFTER CLEANING
Defected seed module.
Troubleshooting: insert a long stick inside the seed sensor. If LED gets dark
for a second: it works. If not: sensor is defected.
THE MONITOR INDICATES IRREGULAR SEED DROPS
WHEN SEEDER STOPPED
Seeds or seed fragments picked up accidentally by the air-flow are detected by
the seed sensor. Sensitivity was set too high adjust higher time limit to
reduce sensitivity.
THERE IS NO SEED DETECTION AT A PROPERLY
WORKING SEEDER, TEST FINDS SEED MODULES, NO DUST
INDICATED
Small sized seeds at low rate seeding adjustment to small seed size and
missing seed time interval to higher.
Module is defected, check it by blinking LED with a long stick inserted
inside.
MAINTENANCE, STORAGE
The most important is keep cables and connectors unhurt and check
then regularly.
Always clean sensors at the end of seeding season, close the end of
extension cable with the waterproof seal.
Do not expose the monitor to direct water, do not store it under 20 C
and above + 40 C temperature, protect it from excessive heat and dust.
Remove the monitor from the cabine for winter and store at a dry,
vapourfree place.
Protect monitor front, display and buttons from strong mechanical
impacts. Clean the monitor with a slightly wet wipe.
There is no battery in the monitor and there are no other parts that
require maintenance.
WARRANTY PROVIDED