The Temperature Cutout Switch
The heater on this fireplace is protected with a safety device to prevent overheating.
Should the heater overheat, a red light (Fig. 1) will be activated and an automatic cutout
will turn the heater off and it will not come back on without being reset. It can be reset by
switching the Main Power switch to OFF and waiting 5 minutes before switching it to ON.
The overheat cutout will be triggered if the filter is dirty. Follow filter maintenance on page 7.
CAUTION
If the heater continuously resets, disconnect the power at the main service panel and call
your local dealer.
NOTE
The heater may emit a slight, harmless odor when first used. This odor is a normal
condition caused by initial heating of internal heater parts and will not occur again.
Maintenance
WARNING
Disconnect all power coming to fireplace at main service panel before attempting
maintenance or cleaning to reduce risk of fire, shock or damage to persons.
NOTE
Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental
burning of skin.
Tool Requirements
Phillips screwdriver
Light Bulb Replacement
Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental
burning of skin.
Light bulbs need to be replaced when you notice a dark section of the flame or when the
clarity and detail of the log exterior disappears. There are four bulbs under the log set
which generate the flames and embers.
Light Bulb Requirements
Quantity of 4 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60
watt rating. Example: GE 60BC or Philips 60CTC.
DO NOT EXCEED 60 WATTS PER BULB.
CAUTION
When handling log only apply force to the ember bed section not directly to the logs.
Helpful Hints
It is a good idea to replace all light bulbs at one time if they are close to the end of their
rated life. Group replacement will reduce the number of times you need to open the unit to
replace light bulbs. Long life bulbs are recommended to reduce the frequency of bulb
changes.
5

Other manuals for Dimplex BF33STP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dimplex BF33STP and is the answer not in the manual?

Dimplex BF33STP Specifications

General IconGeneral
BrandDimplex
ModelBF33STP
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals