www.glendimpex.de 451905.66.01a · FD 0102 EN-9
DHW 300 - DHW 300+ English
7.2 Menu structure
Parameter change: The menu is accessed using the "Menu"
key. In this menu, changes can be made to parameters. The de-
sired menu item is selected with the arrow keys "UP" "DOWN".
The submenu is accessed using the "OK" key.
In this submenu, the parameter that is to be changed can be se-
lected (also using the arrow keys). The "OK" key is used to se-
lect the marked value, which can then be changed via the arrow
keys. The entry is completed by pressing the "OK" key again.
w
Menu block Menu item Parameter Value Description
Settings
Time
00:00
Time setting (24 hour time display)
Date
DD:MM:YYYY
Date setting (Day:Month:Year)
Language
DEUTSCH
ENGLISH
FRANCAIS
ITALIANO
POLSKI
Language selection
Signal tone
On
Off
Setting key tone on / off
Backlight
0 % ... 50 % ...100 %
Setting display backlight
Factory setting
Factory setting reset
Type
DHW 300
DHW 300+
DHW 300D
DHW 300D+
Domestic water heat pump DHW 300
Domestic water heat pump DHW 300+
with additional heat exchanger
Domestic water heat pump DHW 300D
with defrost function
Domestic water heat pump DHW 300D+
with defrost function and additional heat exchanger
Domestic hot
water
Set temperature
25 °C ... 45 °C ... 85 °C
Sets the desired domestic hot water set temperature
Lower
15 °C ... 25 °C ... 40 °C
Sets the minimum hot water temperature, which should also not be
undershot for the duration of a programmed lower process.
Hysteresis
2 K ... 3K ... 10 K
Sets the switching hysteresis
Electric heater
Mode
Delay
Boost period
Boost set temp.
ECO
AUTO
2 h ... 8h...16 h
1 h ... 4h ... 8 h
25 °C ... 60 °C ... 85 °C
ECO: Only switches in the event of an error and with PV b./t., ther-
mal disinfection on
The electric heater is automatically switched on if the domestic hot
water set temperature is not reached within the set delay time in
heat pump operation.
Boost: adjustable time (once, regardless of the Auto/Eco setting)
Boost: adjustable set temperature
Time programs
Therm. disinfection
Thermal disinfection
Start
00:00 ... 23:59
Sets the start time for thermal disinfection (24 hour time display)
Days
Mo ... Su
Sets the day on which thermal disinfection should be activated
Set value
60 °C ... 65 °C ... 85 °C
Sets the set temperature for thermal disinfection.
1st lower
Start
00:00 ... 23:59
Sets the start time for lowering the domestic hot water set temper-
ature
End
00:00 ... 23:59
Sets the end time for lowering the domestic hot water set tempera-
ture
Days
Su ... Mo
Mo - Fr
Sa - Su
Mo - Su
Sets the weekday / block of days on which the lower should be acti-
vated
2nd lower
Start
00:00 ... 23:59
Sets the start time for lowering the domestic hot water set temper-
ature
End
00:00 ... 23:59
Sets the end time for lowering the domestic hot water set tempera-
ture
Days
Su ... Mo
Mo - Fr
Sa - Su
Mo - Su
Sets the weekday / block of days on which the lower should be acti-
vated
(only visible for devices with additional heat exchanger and OFF or Sol selected)