EN-16 451905.66.01a · FD 0102 www.glendimpex.de
English DHW 300 - DHW 300+
8 Performance values
8.1 Heat-up time
3
4
h:min
09:22 09:22
8.2 Energy consumption during heat-up time
3
4
kWh
4.25 4.25
8.3 Power consumption during stand-by period
4
5
W
29 29
8.4 Daily electricity consumption
Q
elec
according to EN 16147 cycle XL
4
5
kWh
5.781 5.781
8.5 COP according to EN 16147 cycle XL
4
5
3.3 3.3
8.6 Reference domestic hot water temperature
4
5
°C
55.9 55.9
8.7 Maximum usable domestic hot water quantity
4
5
litres
421 421
8.8 Load profile
4
5
XL XL
8.9 Water heating energy efficiency ŋ
wh
4
5
%
137 137
1. At temperatures below 7 °C ± 1 °C, the heating element switches on automatically and the heat pump module switches off.
2. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on outlet side).
3. Heating up of nominal volume from 10 °C to 55 °C at air intake temperature of 15 °C and humidity of 70 %
4. The information is valid for a new device with clean heat exchangers
5. At an air intake temperature of 15 °C and 70 % relative humidity.