page 35 of 56ANDIAMO 2.XT (SRC) Hardware Guide - Version 2.1
CHAPTER 4: Operation
MADI input @2 FS or @ 4 FS*
Available for D/A and AES output.
Fallback mode**:
AES input locked > AES signal is source
AES input not locked > analog signal is source
Available for MADI output (01..32 / 33..64)
mute - no input source selected
* MADI @ 2 FS = 32 channels, MADI @ 4 FS = 16 channels
both portions of the MADI stream are used for D/A and AES output
** Fallback mode - see page 36.
Matrix Mode
Channel based routing can be set up via remote control (ANDIAMO Remote). Each
output can be assembled individually from any input sources.
A subset of the Matrix Mode is the Extended Routing feature. It is switchable and
enables both MADI I/Os to be used independently to:
• make full use of all conversion channels at higher sample rates
• double the range of available MADI input channels
• create two individual MADI feeds
The settings of the routing matrix are stored inside the device.
It is possible to toggle between Standard Bank Routing and Matrix Mode without
using the remote control. See „CHAPTER 5: Menu Navigation“ on page 42
LED Code Mode
All 16 LEDs on.
Matrix Mode active
Extended Routing not active
Both MADI outputs work in parallel.
Two LED columns blinking alternately.
Matrix Mode active
Extended Routing active
MADI outputs may transmit individual signals.