User manual in Original
Doc. ref: 500A_MC_am_en_210602
DISPERATOR AB Tel: 08-724 0160 E-mail: info@disperator.se
Mälarvägen 9, 141 71 Segeltorp Web page: www.disperator.se
44 / 44
9.6. Overhaul and Maintenance Intervals
Descripon: Interval: Refers to:
Cleaning of the machine Aer daily use See secon 8.2 in this user manual
Check of the line strainer in the ush
water pipe
First me aer a month use,
then when needed
See secon 8.3.2, item 3 in this user manual
Prevenve maintenance - small
First me aer a month use,
then year 1, year 4, year 7
…........ etc.
For this maintenance (overhaul) please note
that no parts need to be exchanged. See
secon 9.3 in this user manual in terms of:
*Overhaul of protecon safety,
*Overhaul of assembly and connecons,
*Overhaul of all mechanical and electrical
connecons,
*When needed, training of personal.
Prevenve maintenance - medium
Year 2, year 5, year 8 …........
etc.
* Prevenve maintenance – small according
to above.
* Replacement of rubber seals with Posion
No. P14 and P17 (Spare Part No. -05 and -08)
in secon 9.2 of this user manual.
Prevenve maintenance - large
Year 3, year 6, year 9 …........
etc.
* Prevenve maintenance - medium
according to above.
* Replacement of parts included in Service
Package 1 according to secon 9.2 of this
user manual. If needed due to long and hard
operang mes of disposer, please also
inspect if the carrier (Pos. No. P2, Spare Part
No. -18) as described in secon 9.4, item 16
need to be ordered and exchanged. For those
disposer models that have a large inlet with
noise damping seal (shown as Pos. No. 17 in
the table in the end of secon 9.2), please
also consider if this seal due to wear has
lost its elascity and therefore needs to be
replaced.
Replacement of parts due to wear
Aer approx. 9000 operang
hours
Service package 2 according to secon 9.2 in
this user manual
Exchange of other parts When needed