100sx Operators Manual Service - 69
As Needed
Refuel unit as needed. To refuel:
1. Turn engine switch off and let the engine cool
for 3-5 min.
2. Open fuel cap (shown).
3. Insert fuel nozzle and add fuel.
4. Install fuel cap.
Check Wheel Lug Nut Torque
Check wheel lug nut torque before each use.
Tighten to 88-95 ft•lb (108-129 N•m).
Clean Plow Feed Tube
Clean feed tube (shown) every 10 hours.
t44om021w.eps
t44om026w.eps
t44om020w.eps