Service - 114 FX30/FXT30 Operator’s Manual
1000 Hour
1000 Hour
Vacuum System
Change Blower Oil
Change oil every 1000 hours. Change oil more
frequently if working in dusty conditions.
Drain at drain plug (4) while oil is warm.
Add with SGL at fill (2) until oil is at halfway
point on sight glass (3).
Location Task Notes
VACUUM
SYSTEM
Change blower oil SGL
Change hydraulic fluid THF
2
3
4