Complete the Job - 84 FX30/FXT30 Operator’s Manual
Antifreeze Fluid Excavation Unit
Antifreeze Fluid Excavation Unit
Add Antifreeze
Follow these steps for overnight or long-term storage of unit during cold weather.
1. Fill antifreeze tank with a propylene-glycol based antifreeze.
2. Ensure that water tank valve is closed.
3. Open antifreeze tank valve.
4. Connect water pressure hose to wash wand.
5. Start engine.
6. Move water pump switch to on. If freshwater tank is empty, move to bypass.
7. Squeeze wash wand handle and run until antifreeze runs through the wash wand.
8. Move water pump switch to off.
9. Close antifreeze tank supply valve.
10. Turn ignition switch to off.
11. Drain water tank completely.
Reclaim Antifreeze
1. Turn water pressure down.
2. Move water pump switch to on.
3. Put end of wash wand in antifreeze tank.
4. Squeeze wash wand handle and run until water comes out of wand.
5. Move water pump switch to off.