Vacuum and Pothole - 82 FX30/FXT30 Operator’s Manual
Open/Close Tank Door
Open/Close Tank Door
Open
1. If using optional reverse flow mode, turn off engine and ensure handle is down (in VACUUM mode).
2. If tank is tilted, lower tank fully before opening door.
3. Open tank inlet valve.
4. Set hydraulic function switch to door position.
5. Press UP on tethered control.
Close
1. Press DOWN on tethered control until the linkage on both sides of the tank is fully collapsed.
2. Close tank inlet valve.
Crushing weight can cause death or serious injury. Pin
door lock on linkage before servicing.
270-5216
To help avoid injury: Do not raise tank with door held closed only by vacuum. Door may open
suddenly.
NOTICE: Do not drive with tank or door raised.
IMPORTANT: Depressurize tank before emptying cyclonic canister, cleaning filter, clearing hoses or
opening any doors.
Misuse of machine can cause death or serious injury.
Read and understand operator’s manual and all other safety instructions
before use.
273-475