EasyManuals Logo

DITEC CUBIC6 User Manual

DITEC CUBIC6
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
30
IP1812EN
8. Routine maintenance plan
Perform the following operations and checks every 6 months according to intensity of use of the
automation.
Without 230 V~ power supply and batteries if present:
- Lubricate the levers of the gearmotor.
- Lubricate the rotation pivot of the gate leaf.
- Lubricate the gate leaf hinges.
- Check the good conditions of the electric connection.
- Check that the fixing screws of the gearmotor are firmly tightened.
Clean the inside of the cases and check that drain is not clogged.
- Check the value of the capacity of the motor condenser.
Reconnect the 230 V~ power supply and batteries if present:
- Check the power adjustment.
- Check the good operation of all command and safety functions (photocells).
- Check the good operation of the release system.
NOTE: For spare parts, see the spares price list.