15
IP1935EN 2010-07-19
FiJ. 13.1
13. HOLD-TO-RUN FUNCTION MODE
Opening limit switch
Closing limit switch
R1 TM
15 13 12 11 0 1 15689
A
B
ON
OFF
123 4
ON
OFF
123 4 5 6
R1<MAX
TM=MAX
DIP5B=OFF
DIP1A=ON
i
NOTE: to use the control panel in hold-to-run
mode, disconnect terminal 9.
In this case, the openinJ command (1-5) and the closinJ
command (1-6) operate onl\ if Nept pressed, if released
the automation will stop. Automatic closinJ and radio
remote controls are disabled.
N
O
TE: to use the control panel in hold-to-run
m
ode
,
disconnect terminal
9
.