D I V E R S I T E C H O M - G F C M
1.0 - Safety Precautions
1.1 - Caution
This indication refers to matters that have high risk of serious injuries if the system is
installed or operated incorrectly.
All users of Diversi-tech Equipment should comply with all National and Local Fire Codes and/or
other appropriate codes when determining the location and operation of dust control
equipment.
Do not use any voltages other than the ones indicated
Do not cut or damage power cord. Damage to power cord may cause fire or electrical
shock
Flammable Objects-in the event a foreign object should happen to get inside the
cabinet, please take the following actions:
Turn Power Off
Unplug AC cords
Remove object
Resume Operation
Do not disassemble or modify the system – this may impact the warranty clauses
2.0 - Principles of Operation
2.1 - Injection Cleaning System
Principle of Operation:
The Injection Cleaning System (ICS) operates an air nozzle that cleans air filter cartridges. This is
accomplished by extreme compressed air originating from the inside-out through the filter. The
nozzle rotates 360° while moving up and down to insure cleaning of all the surface area of the
air filter.
The cleaning cycle is controlled by a microprocessor based Printed Circuit Board located in the
control box. The microprocessor has been programmed to turn on the cleaning system once
the filter is sealed (“Ready to Clean” appears on the LCD), the start button is pressed and
released. The nozzle will travel from its home position (located at the bottom) through the top
and then back down to home. The home and top positions are sensed by a limit switch and
proximity sensors. Simultaneously, when the gear motor is engaged, an in-line solenoid opens
and allows compressed air to reach the nozzle and the air pulse system. If for some reason the
Cabinet lid is open before the cleaning system has had a chance to terminate the cycle, the
system will shut itself down and resumes from where it left off once the lid is closed and the
filter is sealed.