17. DEFAULT SETTING VALUES
Thermostat probe calibration
Evaporator probe presence
Evaporator probe calibration
Outputs delay at start up
P1-P2 percentage for regulation
Continuous cycle duration
Set point for continuous cycle
(-55.0÷150,0°C) (-67÷302°F)
Compressor ON time with faulty probe
Compressor OFF time with faulty probe
Temperature measurement unit
in=integer; dE= dec.point
P1 – P2 – P3 – P4 – SEt – dtr
Display temperature delay
P1-P2 percentage for display
Kind of interval for defrost
EL=el. heater; in= hot gas
Probe selection for defrost termination
Defrost termination temperature
Interval between defrost cycles
(Maximum) length for defrost
Displaying during defrost
MAX display delay after defrost
First defrost after start-up
Defrost delay after fast freezing
Differential of temperature for forced
activation of fans
10 Pr2
Fan on time with compressor off
Fan off time with compressor off
Probe selection for fan management
Temperat. alarms configuration
rE= related to set;
Ab = absolute
Ab Pr2
MAXIMUM temperature alarm
Minimum temperature alarm
Differential for temperat. alarm recovery
(0,1°C÷25,5°C) (1°F÷45°F)
Delay of temperature alarm at start up
Probe for temperat. alarm of condenser
Condenser for low temperat. alarm
(-55 ÷ 150°C) (-67÷ 302°F)
Condenser for high temperat. alarm
(-55 ÷ 150°C) (-67÷ 302°F)
Differ. for condenser temp. alar. recovery
[0,1°C ÷ 25,5°C] [1°F ÷ 45°F]
Condenser temperature alarm delay
Delay of cond. temper. alarm at start up
Compr. off for condenser low temperature
alarm
n Pr2
Alarm relay polarity (oA3=ALr)
Digital input polarity (13-14)
Digital input 1 configuration (13-14)
EAL, bAL, PAL, dor; dEF; Htr,
AUS
dor Pr1
Digital input alarm delay (13-14)
Number of activation of pressure switch
Compress and fan status when open door
Regulation restart with door open alarm
Differential for Energy Saving
(-30°C÷30°C) (-54°F÷54°F)
Energy Saving cycle start during
workdays
Energy Saving cycle length during
workdays
Energy Saving cycle start on holidays
Energy Saving cycle length on holidays
1
st
workdays defrost start
2
nd
workdays defrost start
3
rd
workdays defrost start
4
th
workdays defrost start
5
th
workdays defrost start
6
th
workdays defrost start
1
st
holiday defrost start
2
nd
holiday defrost start
3
rd
holiday defrost start
4
th
holiday defrost start
5
th
holiday defrost start
6
th
holiday defrost start
* Only for model with real time clock
2
Only for XW60LS with X-REP output