Page 7 of 72
PLACING THE VENDER ON LOCATION
CAUTION: DO NOT TRANSPORT THE VENDER TO OR FROM THE LOCATION WHEN
IT IS LOADED WITH PRODUCT; DAMAGE TO THE VENDER MAY RESULT.
The vender must be located on a solid, flat, and level surface.
The vender must be positioned close enough to an electrical outlet that an extension cord is not required.
If securing the vender to the floor or wall is required, call the Dixie-Narco Factory Service Department
or your Dixie-Narco Representative for suggestions.
LEVEL THE VENDER
Level the vender. When the vender is level, the door can be opened to any position and it will not move
by itself. Open the door to several different positions before deciding that the vender is level. A
carpenter's level will help to verify that the machine is level. Make sure that all of the leveling legs are
in contact with the floor. If you cannot level the vender, select another location. Do not place any
objects under the machine.
DANGER: THE VENDER MUST BE PROPERLY LOCATED AND LEVELED TO
MINIMIZE THE RISK OF INJURY OR DEATH FROM TIPPING IN THE
EVENT OF MISUSE OR VANDALISM.
SPACE THE VENDER
Do not block the rear of the vender. Keep the vender 4 inches (10 cm) from the wall to insure adequate
air flow to the condenser and compressor. At the front of the vender, make sure that nothing obstructs
the air intake at the bottom of the main door. At the rear of the vender, make sure that nothing obstructs
the air exhaust at the bottom of the cabinet.
INSTALLING FLAVOR CARDS
The flavor cards may be inserted one of two ways: 1) in the selection buttons, or 2) in the flavor card
carrier.
1.) Swing the coin changer mounting plate away from the outer door exposing the back of the
select buttons. The flavor cards are inserted in the back of the selection buttons from either
side. Ensure the flavor cards are placed in the select buttons that correspond to the column in
which the product is loaded.
2.) Swing the coin changer mounting plate away from the outer door, exposing the back of the
select panel. Remove the flavor card carrier. Ensure the flavor cards are placed in the select
button flavor card carrier position that corresponds to the column in which the product is
loaded. Install the flavor card carrier back into position.