4. Tilt the spreading system to the side with the cable, insert the spreading system into the aircraft
and rotate. The spreading system needs to be inserted at an angle. DO NOT insert by force.
5. Connect the spreading system cable to the connector in step 2 , ensure a firm and
accurate connection, and then place the protective rubber at the end of cable .
Calibration
Tare Calibration
Make sure to perform tare calibration before rst time use. Otherwise, the weighing accuracy
may be adversely affected. Tare calibration is required if the spread tank is empty but the
weight detected is not zero.
1. Empty the spread tank and place the aircraft on a flat surface. Power on the remote
controller and aircraft.
2. Go to Operation View in the app, select , then , and tap Calibrate.
3. Tap Calibrate and calibration will start automatically. If the calibration is successful, tap
Conrm to complete the calibration.
Empty Tank Calibration
The spreading system has been calibrated before delivery. There is no need to calibrate before
rst time use. Calibration is required if the app incorrectly displays an empty tank warning or
when the app is unable to detect when the tank is empty.
1. Empty the spread tank and place the aircraft on a flat surface. Power on the remote
controller and aircraft.
2. Go to Operation View in the app, tap , then , and tap Calibrate.
3. Tap Calibrate and calibration will start automatically. If the calibration is successful, tap
Conrm to complete the calibration.
To ensure the operation accuracy, it is recommended to perform tare calibration and
empty tank calibration after switching the spraying system to spreading system.