Digital
Overhead Stirrer
User Manual
OS40-Pro
LCD Digital Enhanced Overhead Stirrer
OS40-S
LED Digital Enhanced Overhead Stirrer
(Le Laborantin - réf.702323)
OS20-Pro
LCD Digital Overhead Stirrer
OS20-S
LED Digital Overhead Stirrer
(Le Laborantin - réf.701574)
Please read the User Manual carefully before use, and follow all
operating and safety instructions!
Technical specifications and outline are subject to change without prior
notice.

Other manuals for DLab OS20-S

Questions and Answers

  • T
    tmartinAug 9, 2025
    What to do if my DLab Laboratory Equipment doesn’t stir?
    • D
      Dr. Justin CalderonAug 9, 2025
      If your DLab Laboratory Equipment isn't stirring, first ensure you've set a target speed by rotating the speed control knob and pressing it to start. Also, verify that all cable connections are firmly plugged in. If the issue persists, the belt might be broken, requiring replacement. Alternatively, the driven board or photosensor could be faulty and need replacing.
  • S
    Stacey GreenAug 18, 2025
    How to troubleshoot a DLab OS20-S with no operation response (LED off)?
    • E
      Elizabeth WestAug 18, 2025
      If your DLab Laboratory Equipment shows no operation response and the LED is off, start by checking and connecting the power supply, then power it on again. Ensure that the power switch is turned on. If the problem continues, open the instrument and check all cable connections, reconnecting them as needed.
  • R
    Richard RodgersAug 29, 2025
    Why is the speed control inaccurate on my DLab Laboratory Equipment?
    • C
      chavezloriAug 29, 2025
      If the speed control on your DLab Laboratory Equipment isn't accurate, the drill chuck might be faulty and require replacement. Alternatively, the photosensor could be failing and need replacing.

Summary

Preface

Service

Warranty

Safety Instructions

Proper Use

Inspection

Receiving Inspection

Procedure for checking the instrument for damages upon arrival.

Listing of Items

Details the included components with the main unit.

System Assembly

Install stand

Instructions for assembling the stand and mounting the main unit.

Install stirring impeller

Guidance on attaching the stirring impeller to the drill chuck.

Trial Running

Function

Control

Details the control panel components and their functions for the overhead stirrers.

Display

Overload Protection

Interface and Output (LCD digital)

Faults

Maintenance and Cleaning

Associated standards and regulations

Specifications

Ordering Informations

DLab OS20-S Specifications

General IconGeneral
Max. stirring quantity (H2O)20L
Frequency50/60Hz
Speed range60-1500 rpm
Chuck range diameter0.5-10mm
Overload protectionYes
Ambient temperature5-40°C
Weight3.5 kg
Ambient humidity80%
Motor typeBrushless DC motor