SK-O330-Pro LCD Digital Orbital Shaker
SK-L330-Pro LCD Digital Linear Shaker
VERSION20170311

Questions and Answers

  • D
    Dwayne MitchellAug 7, 2025
    How to fix DLab SK-O330-Pro Laboratory Equipment that can't power on?
    • S
      Steven PittmanAug 7, 2025
      If your DLab Laboratory Equipment won't power on, first ensure the power line is properly plugged in and the power switch is on. If the issue persists, the fuse may be broken and require replacement. Alternatively, the power board, main board, or display screen could be faulty and need replacing.
  • T
    Thomas GalvanAug 15, 2025
    What to do if the DLab SK-O330-Pro instrument doesn’t move?
    • A
      Andrea ZimmermanAug 15, 2025
      If the DLab Laboratory Equipment's instrument doesn't move, first make sure that you have set a target temperature, and that the temperature indicator is on. If the issue continues, it could be due to several reasons: * A failure in the drive board (replace it, referring to chapter 2.5). * A failure in the 24V power board (replace the power board component). * Motor failure (replace the motor). * Broken shrapnel (replace the shrapnel). * A loose or broken belt (replace the belt).
  • R
    Richard HartAug 22, 2025
    Why does my DLab SK-O330-Pro Laboratory Equipment LCD display garbled characters?
    • R
      Richard MasonAug 22, 2025
      If the LCD display of your DLab Laboratory Equipment shows garbled characters, it indicates that the display board is failing and needs to be replaced.
  • K
    Karen FranklinAug 29, 2025
    What causes inaccurate speed and errors on DLab Laboratory Equipment?
    • A
      Adriana CochranAug 29, 2025
      If your DLab Laboratory Equipment instrument speed is inaccurate and shows errors like Self-test, TE1 Ref, TE2 Ref, TE3 Ref, it could be due to a failure in the photosensor, requiring replacement of the heated lid. Another possibility is the photosensor's position is off, requiring adjustment.

Summary

Working Principle

Introduction

Introduces the shaker's function, control panel features, and operational overview.

Composition

Details the separated structural components and exploded view of the SK-O330-Pro shaker.

Removal and Installation of Instrument

Removal

Outlines the necessary tools and initial steps for disassembling the shaker unit.

Main parts illustration

Illustrates main parts and lists spare parts with their corresponding part numbers.

Replacement of master control board

Provides step-by-step instructions for replacing the master control board on the shaker.

Replacement of motor component

Details the procedure for removing and replacing the motor component of the shaker.

Replacement of photoelectric switch

Describes the process for replacing the photoelectric switch on the shaker.

Replacement of power board component

Explains the steps to replace the power board component of the shaker.

Replacement of motor drive board

Provides instructions for replacing the motor drive board on the shaker.

Trouble shooting

Test Method

The instruments does not move

Describes how to diagnose and fix issues where the instrument does not move.

Instrument speed is not accurate

Details steps to check and resolve issues with inaccurate instrument speed.